Building specifications

STRUCTURE

FOUNDATION

Strip foundation

FAÇADE

Plastered, combined with wooden board and façade board.

EXTERIOR WALLS

Concrete-filled hollow concrete blocks.

PARTITION WALLS BETWEEN FLATS

Concrete-filled hollow concrete block or double lightweight block wall.

INTERNAL WALLS OF FLATS

Plasterboard walls on a metal frame.

CEILINGS

Reinforced concrete hollow panel or monolithic concrete ceiling.

The height of suspended ceilings in the flat depends on the communications, but the minimum height is 2.3 m.

ROOF

Reinforced concrete hollow panel, insulation, SBS roll coating and green roof.

BALCONIES AND TERRACES

Balconies are built on cantilevered steel beams.

Flooring of balconies according to the selected package. 

WINDOWS

Triple glazed plastic windows.

COMMUNICATIONS

ENERGY EFFICIENCY

Energy class A, solar panels on the roof.

LIFT

A lift is installed in the building, which is accessible without any steps.

HEATING SYSTEM

The building is heated from the Keila district heating network.

In flats, there is water underfloor heating that can be individually adjusted for each room.

VENTILATION

Energy-efficient forced ventilation with heat recovery system and individual ventilation units for each flat.

WATER AND SEWERAGE

Central domestic water and sewerage, remotely readable water meters.

ELECTRICITY AND WEAK CURRENT

Electrical installation and cabling of data communication systems according to the flat plan, the electric and low-current switchboard is located in the wardrobe of the flat.

Data transmission up to the low-current switchboard in the flat with an optical cable, inside the flat with a CAT cable.